5108: Master compensation trigger FIFO full

Info:
Data type:

Description:
Runtime error when cam automat is active (CMD_CAM_START) if the compensation trigger FIFO for the master axis is full.

Reaction:
See error number 4008.

Cause/Remedy:
Too many false triggers when a FIFO length is at the maximum limit (CAM_MA_S_COMP_TRIG large and (CAM_MA_S_SYNC + CAM_MA_S_COMP) small).
This mostly happens if the trigger window is larger than the half interval (CAM_MA_COMP_TRIG_WINDOW> (CAM_MA_S_SYNC + CAM_MA_S_COMP) / 2).